Life Science
Industrial
Clinical
Educational
Forensic
Semiconductor
Imaging/Video/Software
   •Digital Cameras
   •DFC 295 - Digital
   •DFC 290HD - Digital
   •DFC 310FX - Digital
   •DFC 345FX - Digital
   •DFC 360FX - Digital
   •DFC 400 - Digital
   •DFC 425 - Digital
   •DFC 495 - Digital
   •DFC 500 - Digital
   •Leica IC D - Digital
   •Leica IC80 HD - Digital
   •Jenoptik CMOS - Digital
   •Jenoptik CCD Routine - Digital
   •Jenoptik CCD Research - Digital
   •Jenoptik SpeedXT - Digital
   •MicroPublisher RTV 3.3 - Digital
   •MicroPublisher RTV 5.0 - Digital
   •Photometrics CoolSNAP HQ2 - Digital
   •Photometrics Cascade II:1024 - Digital
   •Photometrics Evolve 128 - Digital
   •Photometrics Evolve 512 - Digital
   •Photometrics QuantEM - Digital
   •QImaging EXi Aqua - Digital
   •QImaging EXi Blue - Digital
   •QImaging QIClick - Digital
   •QImaging Retiga 2000R - Digital
   •QImaging Retiga 4000R - Digital
   •QImaging Retiga SRV - Digital
   •QImaging Rolera MGi - Digital
   •QImaging Rolera Thunder - Digital
   •Analog Cameras
   •Software
   •Video Lenses

   •Accessories
Work Stations/Benches
3D Surface Profiling



Ultrafast, High-Resolution Fluorescence Image Recording

Speed is often the deciding factor for successful imaging in demanding high-resolution image documentation of living cells, molecular processes and rapidly fading fluorescence specimens. The monochrome digital camera Leica DFC360 FX is designed to produce brilliant images at maximum temporal resolution. Thanks to state-of-the-art CCD technology, the new camera system achieves maximum frame rates of 20 fps for full frame up to more than 100 fps in binning mode. The highly sensitive sensor and active Peltier cooling ensure a high dynamic range even for low light intensities. The Leica DFC360 FX is the ideal solution for excellent results in live cell imaging.


  • Fast data transmission via FireWire IEEE1394b
  • 20 frames per second and up to more than 100 frames per second for binning mode due to overlapping mode and interline sensor
  • Highly sensitive 1.4 megapixel CCD in the visible and infrared spectrum
  • Ideal for living cells and rapidly fading fluorescence specimens
  • High linearity over the whole dynamic range and minimum noise
  • Temperature-controlled Peltier cooling
  • The progressive scan of each exposure provides complete full images without disturbing horizontal skipping artefacts
  • 12 or 8 bit digitization option allows the selection of the right degree of detail for the particular application.
  • Partial Scan Mode: Ultrafast read-out of definable areas at full resolution, also in overlapping mode and in combination with binning
  • Camera power supply and fast data transmission via FireWire IEEE1394 b
  • Trigger port for exact synchronization (e.g. via CTR7000)
  • Shutter speeds from 4µs to 10 minutes
  • Long integration times and up to tenfold signal amplification
  • Easy installation on to the microscope
  • Connection of PC and MAC via TWAIN and FireCam
  • Full system integration in Leica Application Suite (LAS) and Leica Application Suite Advanced Fluorescence (LAS AF)
Download this Product's Brochure

Don't have the Acrobat Reader? Download it from adobe.com