Header logo
Contact

Leica EM ACE900

The Leica EM ACE900 is a high-end sample preparation system. Perform freeze-fracture, freeze etching, and e-beam coating in one instrument.

Use the high-resolution carbon/metal mix coatings by e-beam with the rotating cryo stage for any TEM and SEM analysis offering flexible shadowing options.

With a load lock for sample and knife transfer and gate valves for each e-beam source, the instrument can always stay under vacuum which ensures fast and clean working conditions.

The Leica EM ACE900 Freeze Fracture System has a redesigned cooling concept, microtome, shielding, e-beams, load locks, and offers a Leica EM VCT500 connection for protection of the sample during the complete cryo SEM working process.

Freeze Fracture System Leica EM ACE900

Vitrified frozen structures are extremely sensitive to environmental influences and need to be protected from the formation of artefacts. Prepare your samples for detailed image evaluation under optimal conditions:

  • Cold shield around the sample avoids water molecules freezing onto your sample
  • Accurate temperature control during the complete process
  • Clean Knife – fresh blade for each cut avoids contamination
  • Instant, fast e-beam coating, which captures detailed surface information
  • Protected vacuum transfer to other analysis systems

No Boundaries to Research

The Leica EM ACE900 Freeze Fracture System has a redesigned cooling concept, microtome, shielding, e-beams, load locks, and offers a Leica EM VCT500 connection for protection of the sample during the complete cryo SEM working process.

Embedded in a modern user-interface there are no more barriers to operate

Obtain New Insights

  • Biology: membranes, bacteria, cell organelles, proteins
  • Industry: cosmetic products, food, drugs
  • Material research: emulsions, polymers, boundary layers, nano-structures, liquid crystals

Freeze fracture your samples for TEM (replica technique) or cryo SEM (with Leica EM VCT500 transfer)

High Reproducibility, High Specimen Protection

A perfect combination of automation and manual operation (fracturing) make preparation highly reproducible and flexible

All relevant parameters are logged.

Large cryo-shields, sample shutter, optimized sample transfer and cryo microtome ensure highest protection of your samples

Connectivity

Dock the Leica EM VCT500 vacuum cryo transfer system to your Leica EM ACE900 system!

A Leica EM VCT500 dock can be directly attached to the Leica EM ACE900.

With the Leica EM VCT500 shuttle, specimens can be transferred to and from the instrument under perfect conditions for final examination in the cryo-SEM.

Obtain images of the highest resolution within only a few hours.

Fast Operation

Process your samples fast with load locks for:

  • E-beam sources
  • Sample holder
  • Knife

No need to wait until vacuum is reached.

Environmental Responsibility

Our electron microscopy sample preparation systems not only meet highest technical and ergonomic demands, but are also designed to have minimal environmental impact.

What does this mean for the Leica EM ACE900?

  • LN2 consumption during cooling down has been reduced by approx. 87% in comparison to previous instruments.
  • LN2 consumption for cryo work per hour has been reduced by approx. 58% in comparison to previous instruments.
  • Time for cooling down to operation has been reduced by approx. 33% in comparison to previous instruments
  • Reduced size of the instrument leads to less packaging, shipping and transportation costs.
  • Environmental management system DIN EN ISO 14001 has been implemented.

Electrical Data

Supply voltage 100/115/230 V, 50/60 Hz
Maximum current 10 A
Power consumption at idle (while pumping and cooling) 600 W
Power consumption during coating 1 KW

LN2

LN2 consumption (when cold) at -150 °C ~ 2.5 l/h
LN2 to cool down - 2 l
Dewar capacity 25 l, 35l
Dewar pump, two lines separately controllable
LN2 hose insulated, length: 90 cm

Dimensions and Weight

  Width Depth Height Net weight
Basic Instrument 705 mm 710 mm 640 mm approx. 135 kg
…with microscope 705 mm 900 mm 640 mm  
…with VCT500 dock 705 mm 710 mm 640 mm  
…with VCT500 shuttle 1450 mm 710 mm 640 mm  
Instrument table 820 mm 780 mm 750 mm  
LN2 Dewar Ø400 mm   800 mm 12 kg
LN2 Pump Ø180 mm   720 mm  
Nitrogen gas tube dimensions: outer dia. 6 mm, inner dia. 4 mm

Complete the form below for additional information

Yes